Skip to content

Physical Metering & VS Standard (EFRAG)

Aegis Green breaks definitively with theoretical spend-based carbon accounting by relying strictly on the superiority of real physical measurements: recording genuine Watts and Joules consumed at the processor hardware registers.


⚑ Energy Telemetry Architecture Diagram

β”Œβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β” β”Œβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β” β”Œβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”
β”‚ BARE-METAL SERVER β”‚ β”‚ KUBERNETES CLUSTER β”‚ β”‚ CLOUD VPS β”‚
β”‚ (Physical Node) β”‚ β”‚ (EKS, GKE, Bare) β”‚ β”‚ (KVM, QEMU, Cloud) β”‚
β”‚ β”‚ β”‚ β”‚ β”‚ β”‚
β”‚ Physical MSR Registers β”‚ β”‚ Kernel eBPF Kepler Probe β”‚ β”‚ CPU Cycles via /proc/statβ”‚
β”‚ Intel/AMD RAPL (Β±1%) β”‚ β”‚ Per-Pod/Namespace shares β”‚ β”‚ Thermodynamic Model β”‚
β””β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”¬β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”˜ β””β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”¬β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”˜ β””β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”¬β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”˜
β”‚ β”‚ β”‚
β””β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”¬β”€β”€β”€β”€β”€β”΄β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”˜
β–Ό
β”Œβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”
β”‚ SOVEREIGN RUST TELEMETRY AGENT β”‚
β”‚ (apps/telemetry-agent) β”‚
β”‚ β”‚
β”‚ β€’ Compiled native binary with zero GC overhead β”‚
β”‚ β€’ Negligible CPU footprint (< 0.2%) β”‚
β”‚ β€’ Host PID isolation & read-only /proc, /sys mounts β”‚
β”‚ β€’ Continuous high-resolution sampling every 5 seconds β”‚
β””β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”¬β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”˜
β”‚
β–Ό JSON Ingestion (/api/v1/gate/telemetry/energy)
β”Œβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”
β”‚ GO BACKEND & TIMESCALEDB β”‚
β”‚ β”‚
β”‚ β€’ Compressed time-series hypertables (7-day chunks) β”‚
β”‚ β€’ Real-time RTE EcoWatt carbon intensity correlation β”‚
β”‚ β€’ Scope 2 calculation: Energy (kWh), COβ‚‚eq (g), Water (L)β”‚
β””β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”¬β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”˜
β”‚
β”Œβ”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”΄β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”€β”
β–Ό β–Ό
[ AEGIS WEB COCKPIT ] [ ESG EXPORTS & CERTIFICATES ]
β€’ EFRAG compliance radar β€’ Official CSRD / ESG PDF
β€’ Real-time power monitoring β€’ Standardized JSON audit file
β€’ Energy Saver frugal switch β€’ Granular raw CSV export

πŸ”¬ 3 Capture Modes Suited to Any Infrastructure

The Rust telemetry agent automatically selects the most accurate measurement method available on the host environment:

1. Dedicated Bare-Metal Servers: RAPL Registers

On bare-metal physical servers (OVHcloud, Hetzner, Scaleway Dedibox), the agent reads directly from the Linux kernel Intel/AMD RAPL (Running Average Power Limit) interface via /sys/class/powercap/intel-rapl:

  • Captures hardware counters in microjoules for the CPU socket, DRAM memory, and processor cores (Package Energy Status).
  • Certified accuracy within Β±1% against physical testbench power meters.

2. Containerized Clusters: Kepler eBPF Probe

In Kubernetes environments, Aegis integrates with Kepler (Kubernetes Efficient Power Level Exporter) kernel probes:

  • Attributes physical power consumption proportionally based on CPU instruction cycles and context switches for each Namespace, Deployment, or Pod.
  • Empowers engineering teams to attribute carbon footprints directly to individual business microservices.

3. Cloud Virtual Machines (KVM / QEMU): Thermodynamic Modeling

On virtualized instances where hardware MSR registers are hidden by the hypervisor:

  • Samples raw CPU cycle counters directly from /proc/stat (user, system, iowait, idle).
  • Applies a continuous thermodynamic formula calibrated to the VM hardware profile (baseline idle consumption from 12 W up to 48 W under full load per vCPU).
  • Strict CPU Clamping: Bound mathematically within [0.0, 100.0]% to eliminate telemetry spikes caused by hypervisor timer drift or core frequency re-clocking.

πŸ›‘οΈ Host Intrusion Detection & Ingestion Resilience

The Rust telemetry agent (apps/telemetry-agent) couples continuous energy monitoring with kernel-level security telemetry:

1. Process Spawn Monitoring & Benign Worker Filtering

The agent intercepts process fork/exec calls to detect host intrusion attempts in real time:

  • Benign Worker Filtering (is_benign_worker_child_cmd): Distinguishes legitimate runtime wrapper commands (e.g. node spawning sh -c dotenv -e ..., package managers, bundlers) from hostile activity, eliminating false-positive P1 alerts.
  • Adversarial Shell Interception: Unsanctioned subshells (e.g. nc -e /bin/sh, reverse TCP connections, rogue bash -i spawns) immediately trigger emergency alerts in the Cockpit triage stream.

2. High-Availability Ingestion & TimescaleDB DNS Failover

To guarantee uncompromised metrics ingestion even during severe container network strain or DNS flapping:

  • /etc/hosts Direct Resolution: In Go backend ingestion pipelines, the pgx pool directly parses /etc/hosts to bypass transient Docker embedded DNS (127.0.0.11:53) SERVFAIL errors.
  • Persistent IP Caching & KeepAlive: Connection state is backed by 30s TCP keep-alives and cached last-known-good IP addresses, ensuring uninterrupted zero-loss energy ledgering.

🎯 2026 European Regulatory Compliance

Aegis Green transforms raw electrical metrics into audit-ready indicators compliant with European non-financial reporting mandates:

1. Voluntary Standard VS (EFRAG / formerly VSME)

  • Fully aligned with Pillar E3 (Climate Change & Digital Sobriety) under the European CSRD directive for SMEs and mid-caps.
  • Automated computation of Scope 2 emissions (Market-based and Location-based methodologies) alongside datacenter water cooling consumption.

2. RGESN 2024 Framework (Rule 4.15 & Frugal Mode)

  • The Aegis Cockpit features an Energy Saver (Frugal Mode) toggle conforming to Rule 4.15 of the French General Digital Eco-Design Framework (RGESN).
  • Activating Frugal Mode adjusts telemetry sampling intervals, offloads GPU animations, and optimizes database query frequencies to lower server CPU load by up to 25% during off-peak hours.

3. Real-Time RTE EcoWatt Grid Sync & β€œGreen Window”

  • Correlates electrical power consumption with live grid carbon intensity metrics (gCOβ‚‚eq/kWh).
  • Highlights the Green Window (optimal off-peak solar/wind generation periods, typically 11:00 to 15:00) to schedule power-hungry batch workloads, backups, and AI model fine-tuning.

πŸ“‘ Export Formats & Certified Attestation

The Aegis Cockpit provides three audit-ready export formats:

  1. Official ESG Certificate (PDF): An executive document branded with Aegis sovereign styling, detailing total energy consumption (kWh), avoided emissions, and European regulatory compliance. Ready for submission to auditors, investors, and enterprise clients.
  2. Standardized JSON Audit Report (AEGIS-VSME-EFRAG-AUDIT-2026.json): Structured, timestamped data matching official EFRAG schemas for automated ingestion into corporate CSR platforms.
  3. Raw CSV Export: Point-by-point time-series history for statistical analysis and custom business intelligence pipelines.

πŸ“š Articles & Technical References

Explore empirical laboratory measurements and software efficiency research on AIVO: